Automation · Schedules

Off after the shift, on before the shift starts

A schedule switches one or more filter units on or off at a fixed time on selected weekdays. Operation only during production hours, without anyone having to remember.

What schedules do

One action, one time, selected weekdays

Every schedule performs exactly one action: switch on or switch off. A daily rhythm therefore consists of two schedules, for example “Morning start” at 07:00 switch on and “Evening shutdown” at 18:00 switch off. The time refers to the local time zone.

Every schedule is a card with action, time, days, and devices. A master switch disables it temporarily without deleting it, for example during maintenance. Settings can be changed at any time.

Screenshot: Schedule cards Morning start and Evening shutdownScreenshot to follow

Setup

Create in two steps

  1. 1

    Name and devices

    Assign a name, with quick picks: Morning start, Evening shutdown, Lunch break off, Night mode, Weekend plan, Shift change. Then select the devices.

  2. 2

    Time, days, action

    Set the time, choose the weekdays (quick picks “Mon–Fri” or “All days”), and define the action “Switch on” or “Switch off”.

Typical applications

What schedules are made for

Only during production hours

Units run when work is being done. That saves energy without anyone having to switch.

Pre-filtering before the shift starts

The hall is already ventilated when work begins.

Shutdown after the shift

No running overnight when nobody is there anymore.

Shift patterns

Different times per weekday, for example shorter Fridays.

Devices

All remotely controllable units

  • Connected natively

    AirDome, CleanAirTower (self-cleaning), and CleanAirTower SF 9000.

  • Through the KEMPER Connect Bridge

    VacuFil Compact, MaxiFil Clean, Automation Line, AirDome, and CleanAirTower. Bridge machines appear under their machine name.

  • Through the KEMPER Connect IoT Kit

    PLC-controlled filter units such as WeldFil, VacuFil 2000/4000, or KemJet, also under their machine name.

Difference from the Rule Engine

Schedules switch regardless of air quality. If you want to combine time frames and air quality control, use the time windows within a Rule Engine rule (minimum operation, quiet hours, fixed value), because there the automation knows both settings and resolves conflicts according to fixed rules.

Standalone schedules and the Rule Engine should not control the same unit.

Good to know

A schedule has one action (on or off), not a start and end time. There are no exceptions for individual days; instead, a schedule can be disabled temporarily. The time zone is that of the browser when the schedule is created.

Set operating hours, save energy.