Skip to content

New address: Your KEMPER Connect portal with your devices is now at app.kemperconnect.de. Go to portal

KEMPER Connect

KEMPER Connect Bridge

Existing units? Attach it, done.

The KEMPER Connect Bridge is a small gateway that attaches to an existing KEMPER machine and transmits its operating data to KEMPER Connect. Power comes through the machine cable, the connection runs over cellular. No Wi-Fi, no network cabling, no PIN code.

KEMPER Connect Bridge attached to a machine

What makes it special

The Bridge appears as the machine it is attached to

As soon as the Bridge has detected the connected machine, name, product image, dashboard, history, and features automatically switch to that machine type. Nobody has to select the type by hand.

For the user there is no difference between a natively connected and a retrofitted machine: a VacuFil Compact on the Bridge is a VacuFil Compact in KEMPER Connect, with everything that belongs to it. In the Rule Engine, schedules, and automation it is available under its real machine name.

KEMPER Connect Bridge
  1. 1Connect

    Attach the Bridge to the machine and switch the machine on.

  2. 2Green LED

    Pulsing green means: connected, via cellular.

  3. 3Serial number

    “Add device”, type KEMPER Connect Bridge. No PIN.

Supported machines

Which machine becomes which dashboard

Connected machineAppears in KEMPER Connect as
VacuFil CompactVacuFil Compact dashboard: status, filter cleanings, service due, remote start and remote stop
MaxiFil CleanMaxiFil Clean dashboard: filter pressure in mbar as saturation indicator, remote start and remote stop
Automation LineAutomation Line dashboard: motor temperature, cleaning counter, remote start and remote stop
AirDomeAirDome dashboard: volume flow, cleanings, service due, remote start and remote stop
CleanAirTower (self-cleaning)CleanAirTower dashboard: volume flow, cleanings, service due, remote start and remote stop

The CleanAirTower SF 9000 connects natively, not via the Bridge.

Setup

Connected in three steps

  1. 1

    Attach the Bridge

    Attach the Bridge to the machine and switch the machine on. An integrated magnet holds the Bridge on the machine.

  2. 2

    Wait for the status LED

    Pulsing green means: connected. The Bridge uses LTE with automatic fallback to 3G or 2G and transmits every five minutes.

  3. 3

    Register in KEMPER Connect

    “Add device”, choose the device type “KEMPER Connect Bridge”, enter the serial number. No PIN code needed. The serial number is accepted as printed on the device, with or without hyphens, upper or lower case.

As you type, the app shows how many characters are still missing and points out typos. Until the first data arrives, the unit shows “awaiting data” with its connection status and a link to the connection guide.

What a Bridge machine can do

Everything that makes a connected unit

Live dashboard and history

Device status, key figures, and 24-hour history; evaluation by day, week, and month.

Remote start and remote stop

The Bridge passes start and stop commands on to the machine, with a safety prompt and feedback.

Errors and warnings in plain language

A uniform catalog of ten errors and eight warnings, including the IFA-relevant signal “volume flow too low” (IFA: the German Social Accident Insurance institute).

Service countdown

Remaining operating hours until service for VacuFil Compact, MaxiFil Clean, AirDome, and CleanAirTower.

Rule Engine, schedules, automation

Bridge machines are available in all automation tools under their machine name.

Service report

Bridge machines appear with status, hours, and codes on the service page and in the report to the service partner.

For sales and dealers

One device, many machine types

A Bridge can be moved from machine to machine; the dashboard adapts every time. A field sales representative or dealer can thus show the KEMPER Connect experience for many machine types with a single device, at the customer site or at a trade show.

Together with the QR code sign-in on a tablet, the demonstration is set up in a few minutes.

Request a demo

KEMPER Connect Bridge

Hardware

Key data

FeatureValue
Model variants3605615 (Europe, Middle East, Africa, Asia, Australia, New Zealand) and 3605616 (USA, Canada, Mexico)
ConnectionCellular LTE, automatic fallback to 3G/2G; data transmission every five minutes
Power supplyThrough the machine cable; 4-pin M8 connector, cable 0.6 m (5 m extension as accessory)
MountingIntegrated magnet
Protection class and environmentIP 42, operation at +5 °C to +40 °C, indoor use only
Weight0.2 kg
MaintenanceMaintenance-free; firmware updates are carried out by KEMPER

Good to know

The CleanAirTower (self-cleaning) can be started and stopped via the Bridge; dashboard and history use its native data connection. The CleanAirTower SF 9000 connects natively only.

Other devices such as AirWatch, VacuFil 125, or the climate and noise sensors have their own connectivity and do not need a Bridge.

PLC-controlled filter units such as WeldFil, VacuFil 2000/4000, or KemJet connect through the KEMPER Connect IoT Kit.

Which existing units do you have?

We check with you which machines can be retrofitted and show you the Bridge in action.