Devices · Monitoring Kits
Measure noise and indoor climate: set up, add, done
A monitoring kit comes with everything you need: the KEMPER Connect Gateway and five battery-powered wireless sensors. The gateway connects over cellular with a built-in SIM card and needs no configuration. KEMPER Connect rates the readings according to ASR A3.5, the German workplace rule for indoor temperature, and against the action values of 80 and 85 dB(A).

What it looks like in KEMPER Connect
Noise and indoor climate at a glance
Each sensor has its own dashboard. The site pages combine all sensors on a site, with ratings, rankings, and history.
Noise level site page
Site average, peak level, and quietest reading, rated in six levels. The rankings show where it is loudest and where it is quietest.
- History with reference lines at 80 and 85 dB(A)
- Working hours filter, comparison with the previous period, and export
- PDF report on noise exposure

Indoor climate site page
Temperature and humidity with site average and range, rated according to ASR A3.5, plus the mold risk of the room most at risk.
- Minimum temperatures according to ASR A3.5 by work intensity
- Rankings of the warmest and coldest areas
- History with comparison, statistics, and time distribution

The kits
Three starter kits, each with a gateway
Each kit contains a KEMPER Connect Gateway and five sensors per measurement, plus power supply, batteries, and cellular data. Other combinations on request.
Noise Monitoring Kit
Document noise exposure by area and shift.
Included in the kit
- 1 ×KEMPER Connect Gateway with power supply
- 5 ×KEMPER Connect Noise Sensor with batteries
- Cellular data for the gateway
What KEMPER Connect shows
- Equivalent continuous sound level LAeq in six steps, rated against 80 and 85 dB(A)
- Exceedance analysis, working hours filter, PDF report, and export
- Levels only, no audio recording
Climate Monitoring Kit
Document indoor climate according to ASR A3.5 and detect mold risks early.
Included in the kit
- 1 ×KEMPER Connect Gateway with power supply
- 5 ×KEMPER Connect Climate Sensor with batteries and mounting material
- Cellular data for the gateway
What KEMPER Connect shows
- Temperature and humidity, rated according to ASR A3.5
- Mold risk estimate per room in four levels
- Exceedance analysis: time above 26 and 30 °C and outside 40 to 60 % humidity
Noise and Climate Monitoring Kit
Noise and indoor climate through one gateway.
Included in the kit
- 1 ×KEMPER Connect Gateway with power supply
- 5 ×KEMPER Connect Noise Sensor with batteries
- 5 ×KEMPER Connect Climate Sensor with batteries and mounting material
- Cellular data for the gateway
What KEMPER Connect shows
- Everything the Noise and the Climate Monitoring Kit evaluate
- Noise level and indoor climate side by side in the site overview
- One gateway for all ten sensors
In every kit
No setup
Place the gateway, plug in the power supply, add each sensor with its ID and code.
Cellular built in
SIM card in the gateway; Wi-Fi and Ethernet are also possible.
Battery approx. 3 to 5 years
Standard batteries that you replace yourself.
Range approx. 250 to 500 m
LoRaWAN radio inside buildings, one reading every 15 minutes.
Custom kit
More sensors or a different mix? Other combinations are available on request.
Gateway
The KEMPER Connect Gateway
The gateway receives the readings of all sensors in the kit via LoRaWAN and forwards them to KEMPER Connect. All it needs is power from the power adapter; the connection runs over cellular with a built-in SIM card.
No configuration is required. If you prefer to use your own network, Wi-Fi or Ethernet works as well.
- Radio range to the sensors approx. 250 to 500 m indoors
- Cellular with built-in SIM card, alternatively Wi-Fi or Ethernet
- Powered by a power adapter
- One gateway for all sensors in a kit, including noise and indoor climate together

Setup
Up and running in three steps
No configuration, no company network required.
- 1
Set up the gateway
Plug in the power supply, and you are done. The gateway connects over cellular with the built-in SIM card. If you prefer to use your own network, Wi-Fi and Ethernet are also possible.
- 2
Mount the sensors
The sensors transmit to the gateway via LoRaWAN, approx. 250 to 500 m indoors. You attach the Climate Sensor with adhesive or a magnet.
- 3
Add them in KEMPER Connect
Add the sensor with its ID and code. It starts working right away; KEMPER Connect detects the device type and shows the matching dashboard. From then on, a new reading arrives every 15 minutes.
Battery-powered, approx. 3 to 5 years · one reading every 15 minutes
- Cellular, SIM card built in
- Wi-Fi
- Ethernet
- Indoor Climate
- Noise Level
- PDF noise report
Add a sensor with its ID and code, and it starts working right away.
Then assign a name and location description in the settings so that every sensor is easy to find on the site pages.
Sound level only, no audio recording
The KEMPER Connect Noise Sensor measures the sound level only. It does not record audio; conversations are neither recorded nor transmitted. Only level values are sent to KEMPER Connect.
KEMPER Connect Climate Sensor
Connection: KEMPER Connect Gateway (LoRaWAN)Wireless sensor for temperature and relative humidity in the work area. Battery-powered, attached with adhesive or a magnet, transmits every 15 minutes via LoRaWAN to the KEMPER Connect Gateway.

What you see
- Current temperature and humidity as a color-coded display, rated per ASR A3.5: Cold, Cool, Slightly cool, Comfortable, Warm, Hot, Critical, and Too dry, Dry, Comfortable, Humid, Too humid.
- Thresholds and ranges right in the dashboard: minimum temperature 12 to 20 °C depending on work intensity, “Measures recommended” from 26 °C, “Measures required” from 30 °C, comfort band 40 to 60 %. A sentence below the scale states from which work intensity the current value is sufficient.
- Mold risk in four levels (Low to High) with safety margin, mold limit, and dew point per the 80 % criterion from DIN 4108-2 / EN ISO 13788, explicitly marked as an estimate.
- Battery level and radio signal quality.
- 24-hour figures (average, peak with time, average humidity, number of readings), exceedance analysis with duration, share, and number of readings above 26 °C, above 30 °C, and outside the humidity comfort band, climate history with ASR zones, time distribution.
What you evaluate
- Day and week; comparison with the previous period; statistics for temperature and humidity; time distribution.
No PDF report, no export, no working hours filter for indoor climate.
The value
Document the indoor climate against the German workplace rule and detect mold risks before they become visible.

Features at a glance
- Connection
- KEMPER Connect Gateway
- History
- day, week
- Comparison with previous period
- yes
- Working hours filter
- no
- Export
- no
- Site page
- Indoor climate
KEMPER Connect Noise Sensor
Connection: KEMPER Connect Gateway (LoRaWAN)Wireless sensor for the sound level: equivalent continuous sound level LAeq, instantaneous value, and peak value. It measures levels only and does not record audio. Battery-powered, transmits every 15 minutes via LoRaWAN to the KEMPER Connect Gateway.

What you see
- Current level as a color-coded display in six levels: Quiet, Moderate, Elevated, Loud, Very loud, Hazardous. Below it, the instantaneous value and the peak value.
- Thresholds and ranges right in the dashboard: action level 80 dB, OSHA limit 85 dB, six ranges from Quiet (up to 55 dB) to Hazardous (90 dB and above).
- Notices when the action value is reached (80 dB(A), hearing protection recommended) and when the OSHA limit is exceeded (85 dB(A), hearing protection mandatory).
- Battery level and radio signal quality.
- 24-hour summary (average, peak, quietest value), exceedance analysis (duration and share above 80 and above 85 dB), history with noise zones and reference lines, time distribution by level range.
What you evaluate
- Day and week; comparison with the previous period; working hours filter; statistics.
- Export as CSV or Excel, optionally with comparison period.
- PDF noise report for the site with exceedances against 80, 85, and 87 dB(A).
The value
Document noise exposure by area and shift and plan noise protection measures where they are needed.

Features at a glance
- Connection
- KEMPER Connect Gateway
- History
- day, week
- Comparison with previous period
- yes
- Working hours filter
- yes
- Export
- CSV / Excel
- Site page
- Noise level (with PDF report)
Hardware
Key specifications
| Property | KEMPER Connect Gateway | Climate Sensor | Noise Sensor |
|---|---|---|---|
| Purpose | Receives the sensor readings and forwards them to KEMPER Connect | Temperature and relative humidity | Sound level in dB(A): LAeq, instantaneous value, peak value. No audio recording |
| Connection | Cellular with built-in SIM card; alternatively Wi-Fi or Ethernet | LoRaWAN to the gateway | LoRaWAN to the gateway |
| Radio range | Approx. 250 to 500 m indoors to the sensors | Approx. 250 to 500 m indoors to the gateway | Approx. 250 to 500 m indoors to the gateway |
| Power supply | Power adapter | Standard battery, approx. 3 to 5 years, replaced by you | Standard battery, approx. 3 to 5 years, replaced by you |
| Measurement interval | – | 15 minutes | 15 minutes |
| Configuration | None: plug in the power supply | Add in KEMPER Connect with ID and code | Add in KEMPER Connect with ID and code |
The sensors are not waterproof. You attach the Climate Sensor with adhesive or a magnet.
Frequently asked questions
Context
ASR A3.5 and the action values of 80 and 85 dB(A) are rating references. The sensors measure the environment at their installation point, not the personal exposure of individual employees.
Terms explained briefly
- LoRaWAN
- Wireless standard for battery-powered sensors with long range (Long Range Wide Area Network). The sensors send their readings by radio to the gateway.
- Gateway
- Receiving station for the wireless sensors. The KEMPER Connect Gateway forwards the readings to KEMPER Connect over cellular, Wi-Fi, or Ethernet.
- LAeq
- Energy-equivalent continuous sound level: the sound level in dB(A) averaged over a period that contains the same sound energy as the actual, fluctuating level.
- ASR A3.5
- German technical rule for workplaces on room temperature. Names minimum temperatures per work intensity and measures from 26 and 30 °C respectively.